Garofolini (2019) Ankle joint stiffness applsci-09-04100.pdf (2.98 MB)
Ankle joint dynamic stiffness in long-distance runners: effect of foot strike and shoes features
journal contribution
posted on 2021-01-20, 00:05 authored by A Garofolini, S Taylor, P Mclaughlin, Karen MickleKaren Mickle, CA Frigo© 2019 by the authors. Foot strike mode and footwear features are known to affect ankle joint kinematics and loading patterns, but how those factors are related to the ankle dynamic properties is less clear. In our study, two distinct samples of experienced long-distance runners: habitual rearfoot strikers (n = 10) and habitual forefoot strikers (n = 10), were analysed while running at constant speed on an instrumented treadmill in three footwear conditions. The joint dynamic stiffness was analysed for three subphases of the moment-angle plot: early rising, late rising and descending. Habitual rearfoot strikers displayed a statistically (p < 0.05) higher ankle dynamic stiffness in all combinations of shoes and subphases, except in early stance in supportive shoes. In minimal-supportive shoes, both groups had the lowest dynamic stiffness values for early and late rising (initial contact through mid-stance), whilst the highest stiffness values were at late rising in minimal shoes for both rearfoot and forefoot strikers (0.21 ± 0.04, 0.24 ± 0.06 (Nm/kg/°100), respectively). In conclusion, habitual forefoot strikers may have access to a wider physiological range of the muscle torque and joint angle. This increased potential may allow forefoot strikers to adapt to different footwear by regulating ankle dynamic stiffness depending upon the motor task.
Funding
The authors gratefully acknowledge Mizuno Footwear Company for their financial support.
History
Publication Date
2019-01-01Journal
Applied SciencesVolume
9Issue
19Article Number
4100Pagination
15p. (p. 1-15)Publisher
Multidisciplinary Digital Publishing Institute (MDPI)ISSN
2076-3417Rights Statement
The Author reserves all moral rights over the deposited text and must be credited if any re-use occurs. Documents deposited in OPAL are the Open Access versions of outputs published elsewhere. Changes resulting from the publishing process may therefore not be reflected in this document. The final published version may be obtained via the publisher’s DOI. Please note that additional copyright and access restrictions may apply to the published version.Publisher DOI
Usage metrics
Categories
No categories selectedKeywords
Science & TechnologyPhysical SciencesTechnologyChemistry, MultidisciplinaryEngineering, MultidisciplinaryMaterials Science, MultidisciplinaryPhysics, AppliedChemistryEngineeringMaterials SciencePhysicsrunningbiomechanicsfootwearjoint workloadingHUMAN WALKINGMUSCLEBAREFOOTLIMBPATTERNSINJURYWORKMECHANICSTREADMILLREARFOOT