La Trobe

A patient journey audit tool (PJAT) to assess quality indicators in a nuclear medicine service

Download (678.49 kB)
journal contribution
posted on 2024-06-03, 23:20 authored by Kunthi PathmarajKunthi Pathmaraj, J Welch, W Ng, D Lee, Sze LeeSze Lee, A Brink, M Dondi, D Paez, Andrew ScottAndrew Scott
Purpose: To develop a nuclear medicine specific patient journey audit tool (PJAT) to survey and audit patient journeys in a nuclear medicine department such as staff interaction with patients, equipment, quality of imaging and laboratory procedures, patient protection, infection control and radiation safety, with a view to optimising patient care and providing a high-quality nuclear medicine service. Methods: The PJAT was developed specifically for use in nuclear medicine practices. Thirty-two questions were formulated in the PJAT to test the department’s compliance to the Australian National Safety and Quality Health Service Standards, namely clinical governance, partnering with consumers, preventing and controlling health care infection, medication safety, comprehensive care, communicating for safety, blood management and recognising and responding to acute deterioration. The PJAT was also designed to test our department’s adherence to diagnostic reference levels (DRL). A total of 60 patient journey audits were completed for patients presenting for nuclear medicine, positron emission tomography and bone mineral density procedures during a consecutive 4-week period to audit the range of procedures performed. A further 120 audits were captured for common procedures in nuclear medicine and positron emission tomography during the same period. Thus, a total of 180 audits were completed. A subset of 12 patients who presented for blood labelling procedures were audited to solely assess the blood management standard. Results: The audits demonstrated over 85% compliance for the Australian national health standards. One hundred percent compliance was noted for critical aspects such as correct patient identification for the correct procedure prior to radiopharmaceutical administration, adherence to prescribed dose limits and distribution of the report within 24 h of completion of the imaging procedure. Conclusion: This PJAT can be applied in nuclear medicine departments to enhance quality programmes and patient care. Austin Health has collaborated with the IAEA to formulate the IAEA PJAT, which is now available globally for nuclear medicine departments to survey patient journeys.

History

Publication Date

2024-06-01

Journal

European Journal of Nuclear Medicine and Molecular Imaging

Volume

51

Pagination

10p. (p. 1816-1825)

Publisher

Springer Nature

ISSN

1619-7070

Rights Statement

© Crown 2024 This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.

Usage metrics

    Journal Articles

    Licence

    Exports

    RefWorks
    BibTeX
    Ref. manager
    Endnote
    DataCite
    NLM
    DC